捕鱼大作战

Welcome to Jiangsu Xiyuan Instrument Technology Co., Ltd.! We will provide you with excellent service! Sales Hotline: 15358667119
Contact us
Company Name: Jiangsu Xiyuan Instrument Technology Co., Ltd. Address: Dailou Industrial Park, Jinhu County, Huai'an City, Jiangsu Province. Tel: 0517-86888206
Fax: 0517-86888626
Contact: Mr. Yu Mobile: 15358667119
Email: ldcr_1988@163.com
Website: http://qcp555.com

雷达液位计

Product name: radar level gauge

Product model: XY-LD

Product Price:

Product features: XY-LD series radar level gauge is a general-purpose radar level gauge. It is a measuring instrument based on the principle of time travel. The radar wave runs at the speed of light. The running time can be converted into a level signal by electronic components. High-frequency pulses from the probe travel through space at the speed of light

Free consultation: 0517-86888206

Email Us: ldcr_1988@163.com

Details of the radar level gauge :

属于通用型雷达液位计,它基于时间行程原理的测量仪表,雷达波以光速运行,运行时间可以通过电子部件被转换成物位信号。 XY-LD series radar level gauge is a general-purpose radar level gauge. It is a measuring instrument based on the principle of time travel. The radar wave runs at the speed of light. The running time can be converted into a level signal by electronic components. The high-frequency pulse sent by the probe propagates at the speed of light in space. When the pulse hits the surface of the material, it is reflected back and received by the receiver in the meter, and the distance signal is converted into a level signal.
Radar level gauges transmit extremely short microwave pulses with very low energy through an antenna system and receive them. Radar waves travel at the speed of light. The running time can be converted into a level signal by electronic components. A special time extension method can ensure stable and stable measurement in a very short time.
Even if the working conditions are more complicated and there are false echoes, the new micro-processing technology and debugging software can accurately analyze the level echoes.
The antenna receives the reflected microwave pulse and transmits it to the electronic circuit. The microprocessor processes the signal and recognizes the echo generated by the micropulse on the surface of the material. The correct echo signal recognition is completed by intelligent software, and the accuracy can reach millimeter level. The distance D from the surface of the material is proportional to the time travel T of the pulse:
D = C × T / 2
Where C is the speed of light
Because the distance E of the empty tank is known, the level L is: L = ED output
By entering the empty tank height E (= zero), the full tank height F (= full range) and some application parameters to set, the application parameters will automatically adapt the meter to the measurement environment. Corresponds to 4-20mA output.
Application medium:
The intelligent radar level gauge is suitable for non-contact continuous measurement of the level of liquids, slurries and granules. It is suitable for occasions with large changes in temperature and pressure; inert gas and volatilization.
It adopts the measurement method of microwave pulse and can work normally in the range of industrial frequency band. The beam energy is low, and it is installed in various metal, non-metallic containers or pipes without harming the human environment.
Precautions:
1: The measurement range is calculated from the point where the beam touches the tank low, but in special cases, if the tank bottom is concave or tapered, the measurement cannot be performed when the level is below this point.
2: If the medium has a low dielectric constant, when it is at a low liquid level, the bottom of the tank is visible. At this time, in order to ensure the measurement accuracy, it is recommended to set the zero point at a low height of C.
3: It is theoretically possible to measure the position of the antenna tip, but considering the effects of corrosion and adhesion, the final value of the measurement range should be at least 100mm from the antenna tip.
4: For overflow protection, a safety distance can be defined to be attached to the blind zone.
5: The smaller measurement range is related to the antenna.
Radar level gauge installation requirements:
1. Recommended distance (1) from the wall to the outer wall of the short pipe.
2. The tank diameter is 1/6 of the tank diameter, and the smaller distance is 200mm.
3. Do not install above the inlet (4).
Note: The measurement range is calculated from the point where the beam touches the tank low, but in special cases, if the tank low is concave or tapered, the measurement cannot be performed when the level is below this point. If the medium has a low dielectric constant, when the tank is at a low liquid level, the tank can be seen low. At this time, in order to ensure the measurement accuracy, it is recommended to set the zero point at a low height of C. It is theoretically possible to measure the position of the antenna tip, but considering the effects of corrosion and adhesion, the final value of the measurement range should be at least 100 mm from the antenna tip. For overflow protection, a safety distance can be defined to be attached to the dead zone. The smaller measurement range is related to the antenna.
Selection of radar level gauge:
Radar level gauge is a measuring instrument based on the principle of time travel. Radar waves run at the speed of light, and the running time can be converted into a level signal by electronic components. The probe sends out high-frequency pulses and conducts them along the cable and rod probes. When the pulses meet the surface of the material, they are reflected back by the receiver in the meter and the distance signal is converted into a level signal.
Application: liquid, powder, solid particle, gas with floating roof
Measuring range: 70 meters
Process connection: thread, flange
Process temperature: -40-800 °
Process pressure: -1.0-20bar
Accuracy: <0.1%
Frequency range: 6GHZ-80GHZ
Protection level: ExiaⅡC T6 / IP67
Signal output: 4-20mA (two wires)
4-20mA / HART (two wires)
4-20mA / HART (four wires)
Advantages and applications:
1. The radar level gauge can measure liquid and solid media such as: crude oil, slurry, raw coal, pulverized coal, volatile liquids, etc.
2. It can measure in vacuum. It can measure all media with medium constant> 1.2, and the measurement range can reach 70m.
3. The power supply and output signals are passed through a two-core cable (loop circuit), using 4 ... 20mA output or digital signal output;
4. Non-contact measurement installation is convenient to use extremely stable materials, which are durable and reliable, with a reliable resolution of 1mm;
5, not affected by noise, steam, dust, vacuum and other working conditions;
6. It is not affected by the density and temperature of the medium, the process pressure can reach 400bar, and the medium temperature can reach -200 ℃ to 800 ℃;
7. There are various installation methods to choose from: top installation, side installation, bypass installation, waveguide installation;
8. There are many ways to debug: using programming module debugging (equivalent to an analysis and processing instrument), SOFT software debugging, HART handheld programmer debugging, debugging is convenient and fast.
Previous: No more